Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 199
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38697257

RESUMO

OBJECTIVE: Vascular surgery registries report on procedures and outcomes to promote patient safety and drive quality improvement. International registries have significantly contributed to the VASCUNET collaborative abdominal aortic aneurysm (AAA) outcome projects. This scoping review aimed to outline the national registries in vascular surgery that currently participate in the VASCUNET collaborative AAA projects. METHODS: A scoping review of all published VASCUNET AAA studies and validation reports between 1997 and 2024 was undertaken. A survey was conducted among representatives of the international vascular registries contributing to VASCUNET collaborative AAA projects. RESULTS: Currently, vascular registries from 10 countries (Australia, Denmark, Finland, Hungary, Iceland, New Zealand, Norway, Sweden, Switzerland, and the UK) contribute to the current VASCUNET collaborative AAA project, of which eight have national coverage. In the past, three countries (Germany, Malta, and Italy) have participated in previous VASCUNET AAA projects, and a further three countries (Serbia, Greece, and Portugal) have planned participation in future projects. External validity is high for all current registries, with most reporting rates of > 90%. The majority have internal validation processes to assess data accuracy. VASCUNET mediated validation has also been performed by the consortium for five countries to date (Hungary, Sweden, Denmark, Malta, and Switzerland), for which a high degree of external and internal validity was identified. Most registries have established mechanisms for data linkage with national administrative datasets or insurance claims datasets, and contribute to quality improvement through regular reporting to participating centres. CONCLUSION: National vascular registries from nations participating in the VASCUNET collaborative AAA projects are largely comprehensive, with high case ascertainment rates and good quality data with internal quality assurance. This provides a template for new registries wishing to join the VASCUNET collaboration and a benchmark for future research.

2.
J Clin Med ; 13(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38730993

RESUMO

Background: We sought to investigate the differential impact of EVAR (endovascular aneurysm repair) vis-à-vis OSR (open surgical repair) on ruptured AAA (abdominal aortic aneurysm) mortality by sex and geographically. Methods: We performed a retrospective study of administrative data on EVAR from state statistical agencies, vascular registries, and academic publications, as well as ruptured AAA mortality rates from the World Health Organization for 14 14 states across Australasia, East Asia, Europe, and North America. Results: Between 2011-2016, the proportion of treatment of ruptured AAAs by EVAR increased from 26.1 to 43.8 percent among females, and from 25.7 to 41.2 percent among males, and age-adjusted ruptured AAA mortality rates fell from 12.62 to 9.50 per million among females, and from 34.14 to 26.54 per million among males. The association of EVAR with reduced mortality was more than three times larger (2.2 vis-à-vis 0.6 percent of prevalence per 10 percentage point increase in EVAR) among females than males. The association of EVAR with reduced mortality was substantially larger (1.7 vis-à-vis 1.1 percent of prevalence per 10 percentage point increase in EVAR) among East Asian states than European+ states. Conclusions: The increasing adoption of EVAR coincided with a decrease in ruptured AAA mortality. The relationship between EVAR and mortality was more pronounced among females than males, and in East Asian than European+ states. Sex and ethnic heterogeneity should be further investigated.

4.
Ann Surg ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647145

RESUMO

OBJECTIVE: With an increasing life expectancy, more octogenarian patients are referred with complex aortic aneurysms (cAAA). The aim of this study was to evaluate short and mid-term outcomes following fenestrated aortic repair (FEVAR) in octogenarians. SUMMARY BACKGROUND DATA: Few studies looking at octogenarian-specific outcomes with diverging results. METHODS: Retrospective, multicentre cohort study including consecutive patients undergoing elective FEVAR for cAAAs or type IV thoracoabdominal aortic aneurysms between 2007-2022 in eight high-volume centres. Octogenarians vs. non-octogenarians were compared. The primary outcome was 30-day mortality. Secondary outcomes included 1, 2 and 5-year survival and reintervention rates. RESULTS: A total of 729 patients (median age of 74.8 years [IQR 69.2 - 79.14]) were included, 169 (23%) of which were octogenarians, with 316 (43.3%) patients undergoing juxta/pararenal aneurysm repair. Although octogenarians presented less complex but larger (61 mm vs. 58 mm) aneurysms, the number of fenestrations was similar across groups. No differences in in-hospital mortality (4.1 vs. 3.0%), MAE (16.6% vs 12.2%) or reintervention rates (11.2 vs. 10%) were found. Multivariable logistic regression of in-hospital mortality identified BMI (OR 0.66, 95% CI 0.51-0.95, P=0.003), chronic heart failure (OR 7.70, 95% CI 1.36-36.15, P=0.003) and GFR<45 ml/min/1.73 m2 (OR 5.25, 95% CI 1.20-22.86, P=0.027) as independent predictors. Median follow-up was 41 months. The 1, 2 and 5-year survival rates were 91.3%, 81.8% and 49.5% in octogenarians vs 90.6%, 86.5% and 68.8% in non-octogenarian patients (Log-rank: =0.001). Freedom from aortic-related death and freedom from reintervention at five-years were similar across groups (log-rank=0.94 and .76, respectively). Age>80 was not an independent predictor of 30-day or long-term mortality on multivariable and Cox regression analysis. CONCLUSIONS: Elective FEVAR in octogenarians appears to be safe, with similar outcomes as in younger patients. Future studies looking at improved patient selection methods to ensure long-term survival benefits in both octogenarians and younger patients are warranted.

6.
Expert Rev Med Devices ; : 1-8, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38629872

RESUMO

INTRODUCTION: Endovascular treatment of type B aortic dissections (TBAD) has currently acquired a primary therapeutic role when anatomically feasible. The main issue with thoracic endovascular aortic repair (TEVAR) for aortic dissection is the actual nature of the aortic wall, which is structurally compromised and more fragile. Indeed, a wealth of data have shown that TEVAR for TBAD will lead, in a substantial proportion of cases, to a device-related adverse event named distal stent-graft induced new entry (dSINE). AREAS COVERED: Currently available aortic stent-grafts have not been specifically devised for the treatment of aortic dissection. A novel dissection specific stent-graft (DSSG) was developed, which is a custom-made device based on the Zenith Alpha Thoracic platform (Cook Medical). The DSSG has several unique properties that, in principle, make its use optimal in TBAD patients. EXPERT OPINION: TEVAR in the setting of aortic dissections remains technically challenging. The occurrence of dSINE represents a unique complication in this scenario and may lead to high rates of aortic-related adverse events and need for secondary interventions. The use of a novel custom-made DSSG in the setting of chronic TBAD has been proven to be safe, feasible and effective. However, even this approach may fail to completely prevent dSINE formation.

8.
J Vasc Surg ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636609

RESUMO

OBJECTIVE: This study aimed to investigate the incidence of cerebrospinal fluid drainage (CSFD)-related complications specifically in patients undergoing fenestrated and branched endovascular aortic repair (F/B-EVAR). This objective was chosen considering the limitations and uncertainties surrounding its efficacy in preventing spinal cord injury (SCI). METHODS: A systematic review following Cochrane Handbook and PRISMA guidelines was conducted (PROSPERO; #CRD42022359223). Literature searches of MEDLINE, Embase, and Scopus were performed until May 1, 2023, focusing on studies published after January 1, 2000. The inclusion criteria encompassed studies reporting on F/B-EVAR, CSFD, and drain-related complications. Data extraction and quality assessment using the Newcastle-Ottawa scale (NOS) were performed by multiple reviewers to ensure accuracy and reliability. A proportion meta-analysis was conducted to calculate the pooled rate and 95% confidence interval (CI). The primary and secondary outcomes were CSFD-related mortality and morbidity, respectively. RESULTS: Six retrospective, observational, single-center studies were included, totaling 1 079 patients and 730 CSFD placements (all prophylactic except for one). NOS showed a high to moderate risk of bias. The analysis revealed a CSFD-related mortality rate of 1.4% (95%CI 0.0-4.8; I2= 67.7%) and an overall morbidity rate of 25.6% (95%CI 13.6-39.7; I2= 83.2%). The overall major, moderate, and minor estimated complication rates were 6.1% (95%CI 4.1-8.5; I2= 0%), 4.6% (95%CI 2.4-7.3; I2= 33.5%), and 26.4% (95%CI 16.5-37.7; I2= 84.9%), respectively. Severe complications included intracranial hemorrhage (2.8%), spinal hematoma (1.4%), subarachnoid hemorrhage (1.4%), and CSFD-related neurological deficits (1.1%). A pooled estimate of 11.4% for non-functioning drainage was found. CONCLUSION: F/B-EVAR patients showed a notable incidence of CSFD-related death and substantial morbidity. This study highlights the limitations of the available data, the high prevalence of complications associated with CSFD, and the need for further research to better understand the risks and benefits of CSFD in F/B-EVAR. This calls for careful consideration regarding the routine use of prophylactic drainage due to the accumulating evidence of the risks associated with CSFD without proven benefit in this specific contex.

10.
J Vasc Surg ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38462062

RESUMO

OBJECTIVE: management of follow-up protocols after endovascular aortic repair (EVAR) varies significantly between centers and is not standardized according to sac regression. By designing an international expert-based Delphi consensus, the study aimed to create recommendations on follow-up after EVAR according to sac evolution. METHODS: Eight facilitators created appropriate statements regarding the study topic that were voted, using a 4-point Likert scale, by a selected panel of international experts using a three-round modified Delphi consensus process. Based on the experts' responses, only those statements reaching a grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final document. RESULTS: One-hundred and seventy-four participants were included in the final analysis, and each voted the initial 29 statements related to the definition of sac regression (Q1-Q9), EVAR follow-up (Q10-Q14), and the assessment and role of sac regression during follow-up (Q15-Q29). At the end of the process, 2 statements (6.9%) were rejected, 9 statements (31%) received a grade B consensus strength, and 18 (62.1%) reached a grade A consensus strength. Of 27 final statements, 15 (55.6%) were classified as grade I, whereas 12 (44.4%) were classified as grade II. Experts agreed that sac regression should be considered an important indicator of EVAR success and always be assessed during follow-up after EVAR. CONCLUSIONS: Based on the elevated strength and high consistency of this international expert-based Delphi consensus, most of the statements might guide the current clinical management of follow-up after EVAR according to the sac regression. Future studies are needed to clarify debated issues.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38382695

RESUMO

OBJECTIVE: To determine the peri-operative mortality rate for intact and ruptured abdominal aortic aneurysm (AAA) repair in 10 countries and to compare practice and outcomes over a six year period by age, sex, and geographic location. METHODS: This VASCUNET study used prospectively collected data from vascular registries in 10 countries on primary repair of intact and ruptured AAAs undertaken between January 2014 and December 2019. The primary outcome was peri-operative death (30 day or in hospital). Logistic regression models were used to estimate the association between peri-operative death, patient characteristics, and type of procedure. Factors associated with the use of endovascular aortic aneurysm repair (EVAR) were also evaluated. RESULTS: The analysis included 50 642 intact and 9 453 ruptured AAA repairs. The proportion of EVARs for intact repairs increased from 63.4% in 2014 to 67.3% in 2016 before falling to 62.3% in 2019 (p < .001), but practice varied between countries. EVAR procedures were more common among older patients (p < .001) and men (p < .001). Overall peri-operative mortality after intact AAA repair was 1.4% (95% confidence interval [CI] 1.3 - 1.5%) and did not change over time. Mortality rates were stable within countries. Among ruptured AAA repairs, the proportion of EVARs increased from 23.7% in 2014 to 35.2% in 2019 (p < .001). The average aortic diameter was 7.8 cm for men and 7.0 cm for women (p < .001). The overall peri-operative mortality rate was 31.3% (95% CI 30.4 - 32.2%); the rates were 36.0% (95% CI 34.9 - 37.2%) for open repair and 19.7% (95% CI 18.2 - 21.3%) for EVAR. This difference and shift to EVAR reduced peri-operative mortality from 32.6% (in 2014) to 28.7% (in 2019). CONCLUSION: The international practice of intact AAA repair was associated with low mortality rates in registry reported data. There remains variation in the use of EVAR for intact AAAs across countries. Overall peri-operative mortality remains high after ruptured AAA, but an increased use of EVAR has reduced rates over time.

12.
J Vasc Surg Cases Innov Tech ; 10(2): 101426, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375347

RESUMO

In situ laser fenestration (ISLF) has emerged as a promising technique for emergent revascularization of the left subclavian artery in the case of thoracic endovascular aortic repair coverage, presenting excellent technical success rates in most studies. We describe a case of ISLF of the Thoraflex Hybrid frozen elephant trunk device to achieve immediate left subclavian artery revascularization. We demonstrate the feasibility and technical success of using ISLF in this setting, providing a less invasive alternative to conventional surgical revascularization when required.

13.
Eur J Vasc Endovasc Surg ; 67(2): 192-331, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38307694

RESUMO

OBJECTIVE: The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS: The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS: A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION: The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.

14.
Br J Surg ; 111(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38198155

RESUMO

BACKGROUND: Patients with abdominal aortic aneurysms are at high risk of cardiovascular events. Although statin therapy is indicated for most of these patients, no specific recommendation regarding the intensity of therapy exists. The aim of this study was to assess the possible effect of statin therapy on survival of patients undergoing abdominal aortic aneurysm repair and to investigate if high-intensity statin therapy was superior to low-moderate-intensity therapy. METHODS: Data from nationwide Swedish registers on hospital admissions, operations, and medications for patients undergoing elective abdominal aortic aneurysm repair from 2006 to 2018 were collected. The effect of statin use was evaluated in three separate propensity score matched cohorts: perioperative mortality was analysed according to whether patients were on statins before abdominal aortic aneurysm repair or not; long-term survival was assessed according to whether patients were on statins during follow-up or not; and, for those on statins after surgery, long-term survival was analysed according to whether patients were on high-intensity or low-moderate-intensity statin therapy. RESULTS: Preoperative statin use did not reduce 90-day perioperative mortality (OR 0.99, 95% c.i. 0.77 to 1.28), whilst there was a marked benefit regarding long-term survival for postoperative statin users (HR 1.43, 95% c.i. 1.34 to 1.54). High-intensity statin therapy had no advantage over low-medium-intensity statin therapy with regards to long-term survival (HR 1.00, 95% c.i. 0.80 to 1.25). CONCLUSION: In this nationwide propensity score matched cohort study, preoperative statin treatment had no benefit regarding 90-day perioperative survival, but postoperative statin treatment markedly improved long-term survival. No additional benefit regarding high-dose statin treatment could be confirmed in this analysis.


Assuntos
Aneurisma da Aorta Abdominal , Inibidores de Hidroximetilglutaril-CoA Redutases , Procedimentos de Cirurgia Plástica , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Estudos de Coortes , Aneurisma da Aorta Abdominal/cirurgia , Hospitalização
15.
Surg Open Sci ; 17: 30-34, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38274239

RESUMO

Background: Surgery is a stressful exercise, and the experience of occupational stress may have impacts on surgical performance, and surgeon well-being. Music is played in operating theatres (OTs) throughout the world, and while it may improve surgical performance, and reduce clinician stress within the OT, concerns exist over its distracting and noise-creating properties. Methods: In this prospective observational study, between May to August 2022, Vascular, General and Paediatric surgeons and registrars in Australia and Aotearoa New Zealand (AoNZ) responded to a survey investigating the way they use music, and their perceptions and attitudes towards its effect on the OT environment. Binomial logistic regression and Chi squared tests of association were performed, accepting p < 0.05 as significant. Results: In this cohort of 120 surgeons, 45 % were vascular specialists, 30 % were female and 59 % were consultant surgeons. The most commonly preferred music genres were easy listening and pop. Over 75 % of surgeons enjoyed having music in their OTs with the majority reporting it improved their temperament, how mentally fatiguing a procedure felt and how anxious or stressed they felt. Vascular surgeons were more likely to believe music had a positive influence on communication than their general and paediatric surgery colleagues (p < 0.01). Registrars had significantly higher odds of believing music had a positive effect on their temperament, and how stressed and anxious they felt when operating, when compared to consultants (p < 0.05). Conclusions: This study provides a window into the surgeons' use of and attitudes towards intra-operative background music and its effect on stress and cognitive load in Australia and AoNZ. While overall, music is viewed positively by this cohort, there was some difference seen across specialties and level of experience. Further subjective and objective data in this field may provide useful information to guide hospital policy and inform pathways for clinician wellbeing.

16.
Eur J Vasc Endovasc Surg ; 67(1): 99-104, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37704100

RESUMO

OBJECTIVE: The use of intravascular ultrasound (IVUS) reduces contrast medium use and radiation exposure during conventional endovascular aneurysm repair (EVAR). The aim of this study was to evaluate the safety and efficacy of IVUS in detecting bridging stent graft (bSG) instability during fenestrated and branched EVAR (F/B-EVAR). METHODS: This was a prospective observational multicentre study. The following outcomes were evaluated: (1) technical success of the IVUS in each bSG, (2) IVUS findings compared with intra-operative angiography, (3) incidence of post-operative computed tomography angiography (CTA) findings not detected with IVUS, and (4) absence of IVUS related adverse events. Target visceral vessel (TVV) instability was defined as any branch or fenestration issues requiring an additional manoeuvre or re-intervention. Any IVUS assessment that detected stenosis, kinking, or any geometric TVV issue was considered to be branch instability. All procedures were performed in ad hoc hybrid rooms. RESULTS: Eighty patients (69% males; median age 72 years; interquartile range 59, 77 years) from four aortic centres treated with F/B-EVAR between January 2019 and September 2021 were included: 70 BEVAR (21 off the shelf; 49 custom made), eight FEVAR (custom made), and two F/B-EVAR (custom made), for a total of 300 potential TVVs. Two TVVs (0.7%) were left unstented and excluded from the analysis. The TVVs could not be accessed with the IVUS catheter in seven cases (2.3%). Furthermore, 17 (5.7%) TVVs could not be examined due to a malfunction of the IVUS catheter. The technical success of the IVUS assessment was 91.9% (274/298), with no IVUS related adverse events. Seven TVVs (2.5%) showed signs of bSG instability by means of IVUS, leading to immediate revisions. The first post-operative CTA at least 30 days after the index procedure was available in 268 of the 274 TVVs originally assessed by IVUS. In seven of the 268 TVVs (2.6%) a re-intervention became necessary due to bSG instability. CONCLUSION: This study suggests that IVUS is a safe and potentially valuable adjunctive imaging technology for intra-operative detection of TVV instability. Further long term investigations on larger cohorts are required to validate these promising results and to compare IVUS with alternative technologies in terms of efficiency, radiation exposure, procedure time, and costs.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Stents , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Desenho de Prótese , Ultrassonografia de Intervenção
18.
Eur J Vasc Endovasc Surg ; 67(4): 620, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38040104
19.
J Vasc Surg ; 79(4): 748-754.e2, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38013041

RESUMO

BACKGROUND: The mortality after ruptured abdominal aortic aneurysm (rAAA) repair is high, despite improvements in perioperative care, centralization of emergency vascular surgical services, and the introduction of endovascular aneurysm repair (EVAR). The diameter of intact AAA has been shown to be a predictor of short- and long-term survival. The aim of this study was to analyze the impact of AAA diameter on mortality for rAAA repair using contemporary data collected from the International Consortium of Vascular Registries and compare outcomes by sex and the type of repair patients received. METHODS: Prospective registry data on repair of rAAA from seven countries were collected from 2010 to 2016. The primary outcome was perioperative mortality after EVAR and open surgical repair (OSR). Data were stratified by type of repair and sex. Logistic regression models were used to estimate odds ratio (OR) for the association between AAA diameter and perioperative mortality and the association between type of repair and mortality. Multivariable logistic regression models were used to adjust for differences in patient characteristics. RESULTS: The study population consisted of 6428 patients with a mean age ranging from 70.2 to 75.4 years; the mean AAA diameter was 7.7 ± 1.8 cm. Females had a significantly smaller AAA diameter at presentation compared with males (6.9 ± 1.6 cm vs 7.9 ± 1.8 cm; P < .001). who underwent OSR had larger AAA diameters compared with those who underwent EVAR (P < .001). Females who underwent repair were significantly older (P < .001). Males were more likely to have cardiac disease, diabetes mellitus, and renal impairment. Overall, AAA diameter was a predictor of mortality in univariate and multivariate analysis. When analyzing EVAR and OSR separately, the impact of AAA diameter per cm increase on mortality was apparent in both males and females undergoing EVAR, but not OSR (EVAR: male OR, 1.09 [95% confidence interval, 1.03-1.16] and EVAR: female OR, 1.17 [95% confidence interval, 1.02-1.35]). The early mortality rate for males and females who underwent EVAR was 18.9% and 25.9% (P < .001), respectively. The corresponding mortality for males and females who underwent OSR was 30.2% and 38.6% (P < .001), respectively. CONCLUSIONS: In these real-world international data, there is a significant association between rAAA diameters and early mortality in males and females. This association was more evident in patients undergoing EVAR, but not shown in OSR. Despite improvements in overall AAA repair outcomes, the risk of mortality after rAAA repair is consistently higher for females.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Sistema de Registros , Estudos Retrospectivos , Complicações Pós-Operatórias/cirurgia
20.
Ann Vasc Surg ; 101: 164-178, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38154491

RESUMO

BACKGROUND: The aims of this study were: i) to assess fragility indices (FIs) of individual randomized controlled trials (RCTs) that compared paclitaxel-based drug-coated balloons (DCBs) or drug-eluting stents (DESs) versus standard endovascular devices, and ii) to meta-analyze mid-term and long-term safety and efficacy outcomes from available RCT data while also estimating the FI of pooled results. METHODS: This systematic review has been registered in the PROSPERO public database (CRD42022304326 http://www.crd.york.ac.uk/PROSPERO). A query of PubMed (Medline), EMBASE (Excerpta Medical Database), Scopus, and CENTRAL (Cochrane Central Register of Controlled Trials) databases was performed to identify eligible RCTs. Rates of primary patency (PP) and target lesion revascularization (TLR) were assessed as efficacy outcomes, while lower limb amputation (LLA) consisting of major amputation that is. below or above the knee and all-cause mortality were estimated as safety outcomes. All outcomes were pooled with a random effects model to account for any clinical and study design heterogeneity. The analyses were performed by dividing the RCTs according to their maximal follow-up length (mid-term was defined as results up to 2-3 years, while long-term was defined as results up to 4-5 years). For each individual outcome, the FI and reverse fragility index (RFI) were calculated according to whether the outcome results were statistically significant or not, respectively. The fragility quotient (FQ) and reverse fragility quotient (RFQ), which are the FI or RFI divided by the sample size, were also calculated. RESULTS: A total of 2,337 patients were included in the systematic review and meta-analysis. There were 2 RCTs examining DES devices and 14 RCTs evaluating different DCBs. For efficacy outcomes, there was evidence that paclitaxel-based endovascular therapy increased the PP rate and reduced the TLR rate at mid-term, with a calculated pooled risk ratio (RR) of 1.66 for patency (95% CI, 1.55-1.86; P < 0.001), with a corresponding number needed-to-treat (NNT) of 3 patients (95% CI, 2.9-3.8) and RR of 0.44 for TLR (95% CI, 0.35-0.54; P = 0.027), respectively. Similarly, there was evidence that paclitaxel-based endovascular therapy both increased PP and decreased TLR rates at long-term, with calculated pooled RR values of 1.73 (95% CI, 1.12-2.61; P = 0.004) and 0.53 (95% CI, 0.45-0.62; P = 0.82), respectively. For safety outcomes, there was evidence that paclitaxel-based endovascular therapy increased all-cause mortality at mid-term, with a calculated pooled RR of 2.05 (95% CI, 1.21-3.24). However, there was no difference between treatment arms in LLA at mid-term (95% CI, 0.1-2.7; P = 0.68). Similarly, neither all-cause mortality nor LLA at long-term differed between treatment arms, with a calculated pooled RR of 0.66, 1.02 (95% CI, 0.31-3.42) and 1.02 (95% CI, 0.30-5.21; P = 0.22), respectively. The pooled estimates of PP at mid-term were robust (FI = 28 and FQ = 1.9%) as were pooled rates of TLR (FI = 18 and FQ = 0.9%). However, when safety outcomes were analyzed, the robustness of the meta-analysis decreased significantly. In fact, the relationship between the use of paclitaxel-coated devices and all-cause mortality at mid-term showed very low robustness (FI = 4 and FQ = 0.2%). At 5 years, only the benefit of paclitaxel-based devices to reduce TLR remained robust, with an FI of 32 and an FQ of 3.1%. CONCLUSIONS: The data supporting clinical efficacy endpoints of RCTs that examined paclitaxel-based devices in the treatment of femoral-popliteal arterial occlusive disease were robust; however, the pooled safety endpoints were highly fragile and prone to bias due to loss of patient follow-up in the original studies. These findings should be considered in the ongoing debate concerning the safety of paclitaxel-based devices.


Assuntos
Angioplastia com Balão , Arteriopatias Oclusivas , Doença Arterial Periférica , Humanos , Artéria Poplítea/diagnóstico por imagem , Paclitaxel/efeitos adversos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA